Open problems

What is not answered yet.

Each problem says what is known, what is not, and what would settle it. When one is answered it becomes a finding.

Open since 12 October 2026 · PLC Runtime

How much of the language can the compute VM be shown to run identically?

Of the 6,531 conformance cases run against outside references, the equivalence gate admitted 228 to the compute VM. VM and interpreter agreed on all 228; for the rest the VM has no conformance evidence.

The question

The runtime has two engines for Structured Text: the interpreter and a compiled compute VM. A task moves to the VM only after an equivalence gate has run it on both and found them byte-identical. The function conformance suite checks builtins against outside references (the OSCAT manual, IEC 61131-3, CODESYS behaviour and protocol specifications). When it runs its cases through both engines, the gate admits only some of them to the VM.

What is known

On the run of 2026-10-27, 228 of the 6,531 cases run were admitted to the VM, and VM and interpreter agreed on all 228. That is evidence of VM conformance for those 228 cases and nothing more.

What would settle it

Either widen what the gate can admit, so more of the corpus runs on both engines, or show for each refused construct why the VM must refuse it. The measure is the admitted share of the corpus, with agreement held at 100 %.

Sources: Overseer board, st-function-conformance (run of 2026-10-27, v1.0.1844) (docs/OVERSEER.md) · Conformance case corpus (tests/conformance/)

Open since 2 September 2026 · Data Logger & Historian

Can a store-and-forward reader keep a late-write grace without re-reading it every tick?

The forwarder still decodes about 11.7 rows for every row it sends, because each 5 s pass re-reads the newest minute of history to catch writes that arrive up to 60 s late.

The question

The forwarder’s cursor waits 60 s behind real time, so that rows written late are not skipped. As a result, each 5 s pass decodes the newest minute file and the live minute’s segments again, just to find the rows from the last tick. After the fix, that is one to three percent of a core. It is small, and it is the last of the amplification; by design it should grow with the number of tags forwarded, though that has not been measured.

What would settle it

A per-file test of which cursors a file can still serve, comparing each tag’s cursor against the file’s footer bounds. That would narrow the set of wanted tags per file and let the tag index seek instead of scan. The measure is the raw_read amplification the store already reports, which should approach 1× without shortening the grace. A shorter grace would trade away data safety, and that is not the trade being sought.

Finding: A historian forwarder that cost a core: 13 million rows decoded to ship 7 thousand →
Sources: Performance record, 'What is left' (docs/perf/forward-path/README.md) · Design status, row 14 (cost of the remaining amplification) (docs/design/STATUS.md)

Open since 27 July 2026 · PLC Runtime, Digital Twin

What is the rest of the cavity solver's amplitude deficit?

At 129×129 and Re = 1000, the upwind blend explains only a minority of the 13.8 % damping. The rest is either grid-dependent truncation or the artificial-compressibility formulation, and one run can tell them apart.

The question

Cutting the upwind blend from θ = 0.30 to 0.10 at a fixed grid took the amplitude deficit from 13.8 % to 11.2 %. Most of the deficit does not depend on θ. The leading candidates are truncation error in the second-order central terms, and the artificial-compressibility pressure coupling. The coupling is itself calibrated on the grid spacing, so both candidates depend on h.

What would settle it

A 257×257 run at θ = 0.30, on eight tiles. If the deficit falls by roughly the θ-independent share, that share is grid-dependent truncation. If it barely moves, the cause is the formulation or 32-bit precision, and more resolution is the wrong fix.

A third θ point (0.20, or 0.0 if it stays stable) would test whether the two-point linear split holds at all.

Also open

The Re = 1000 reference column needs ratifying against the paper itself. The 51×51 runs at Re = 400, 3200 and 5000 need their centerlines scored.

Finding: Navier–Stokes in Structured Text: the lid-driven cavity against Ghia, Ghia & Shin (1982) →
Sources: Validation record, P2 and P3 (projects/cfd/VALIDATION.md)